wangshuang Publish time 2019-4-12 10:03:57

the range of voltage values that can be measured by 6022BE

hello every one my name is andres gonzalez
I bought the oscilloscope 6022BE
i have some questions about your product (oscilloscope 6022BE)
is posible measure the voltage AC ?
for example 24VAC
wich is the funcion of USBXI port?
I gratefull your help
thank you



wangshuang Publish time 2019-4-12 10:05:35

The maximum measurement voltage is ±5V.

It can't measure the voltage 24VAC.

USBXI port is used to connect with combined instrument, like this: http://hantek.com/en/ProductDetail_17_126.html

ying Publish time 2022-4-15 08:46:12




The max. measure voltage is from -5V to +5V without any attenuation of Hantek6022.
If you need meaure AC 24V, you need use 10:1 attenuation together with 10x probe.