WisdomAugust Publish time 2020-1-9 08:55:13

? You can use noise as the modulating waveshape, but you cannot use noise, or dc as the carrier waveform. ? If you select an arbitrary waveform as the modulating waveshape, the waveform is automatically limited to 4K points. Extra waveform points are removed using decimation. ? Front-Panel Operation: After enabling AM, press the Shape Modulating Waveform Frequency The function generator will accept an internal or external modulation source for AM. ? Modulating frequency (internal source): 2mHz to 50kHz. The default is 100 Hz. ? Front-Panel Operation: After enabling AM, press the AM Freq softkey, and then use the numeric keyboard or direction keys and knob to input the desired frequency value.

WisdomAugust Publish time 2020-1-10 10:03:24

Modulation Depth The modulation depth is expressed as a percentage and represents the extent of the amplitude variation. At 0% depth, the output amplitude is half of the selected value. At 100% depth, the output amplitude equals the selected value. ? Modulation depth: 0% to 120%. The default is 100%. ? Note that even at greater than 100% depth, the function generator will not exceed 10V peak on the output (into a 50? load). ? If you select the External modulating source, the carrier waveform is modulated with an external waveform. The modulation depth is controlled by the ±2.5V signal level present on the front-panel Sync/Mod/Trig connector. For example, if you have set the modulation depth to 100%, then when the modulating signal is at +2.5 volts, the output will be at the maximum amplitude. When the modulating signal is at -2.5 volts, then the output will be at the minimum amplitude. ? Front-Panel Operation: After enabling AM, press the AM Depth softkey. Then use the knob or numeric keypad to enter the depth.

WisdomAugust Publish time 2020-1-13 08:09:35

How to Use the Sweep Function of HDG6000B?


WisdomAugust Publish time 2020-1-14 08:25:57

To Output a Frequency Sweep In the frequency sweep mode, the function generator “steps” from the start frequency to the stop frequency at a sweep rate which you specify. You can sweep up or down in frequency, and with either linear or logarithmic spacing. For this example, you will output a swept sine wave from 1 Hz to10 Hz. You will not change the other parameters from their default settings: internal sweep trigger, linear spacing, and 1 second sweep time.Sweep display on the generator

WisdomAugust Publish time 2020-1-15 08:01:18

Sweep display on the oscilloscope

WisdomAugust Publish time 2020-1-16 09:00:16

1 Select the function and amplitude for the sweep. For sweeps, you can select sine, square, ramp, or arbitrary waveforms (pulse, noise, and dc are not allowed). For this example, select a sine wave with an amplitude of 200 mV. The Sine key light when using a sine wave.

Sine Sweep display on the generator

WisdomAugust Publish time 2020-1-17 08:05:48

Sine Sweep display on the oscilloscope

Pages: 1 2 3 4 [5]
View full version: How to Use the Modulated Waveform Function of HDG6000B?