filipj Publish time 2021-12-15 01:30:23

DSO2D10 - FFT - mismatch between background scale and cursor

Edited by filipj at 2021-12-15 03:04

Hello,

I have purchased recently DSO2D10.
I was doing fft of a signal and I wanted to measure its level with "cursor" utility.
There seems to be a mismatch metween a scale that can be seen in backgroung and readings of "cursor".
On photo we can see that cursors are pointing 2.2 and 1.2 V on the grid's Y axis, but the readings of "cursor" are 1 and 2 V.
This seems like a bug.

https://www.eediscuss.com/forum.php?mod=image&aid=4708&size=300x300&key=9c043fa2eda6acbb&nocache=yes&type=fixnone



filipj Publish time 2021-12-15 01:39:46

It looks like there been bugs like this one in the past:
https://www.eediscuss.com/forum.php?mod=viewthread&tid=9346

wangshuang Publish time 2021-12-15 14:52:42




It has been feedback, please wait for the new firmware released, thanks.

wangshuang Publish time 2021-12-17 14:11:29




Firmware has been released, you can download on this link:
http://hantek.com/products/detail/17182

filipj Publish time 2021-12-29 19:58:41

Great. It works. Thank you !