uFedor Publish time 2022-6-19 02:44:58

Hantek6254 operation details

Edited by uFedor at 2022-6-19 10:18

Hello!
Model in question: Hantek6254EU
In the Hantek6000EU_Manual_EN.pdf, Appendix A: Specifications it is written:

Memory Depth128M/CH;62M/2CH;32M/4CH

Questions:

[*]How exactly number of channels can be configured?
[*]Does it mean that per-channel sampling rate for 2CH is 500MS/s and for 1CH – 1GS/s?
[*]Can you please provide a captured trace in 1CH mode of 8ns signal like below:

https://www.eediscuss.com/forum.php?mod=image&aid=5119&size=300x300&key=cdb7ef147a6c701f&nocache=yes&type=fixnone
Bestregards,FedorBaev



Jing Publish time 2022-6-20 19:27:34




6254EU has 4 channels.
Open one channel, the sample rate is 1G, open two channels to 500M, open 3 or 4 channels to 250M.
Could you please describe your third question in more detail?

uFedor Publish time 2022-6-21 09:17:44

Thank you for the response.

You wrote:
> Open one channel, the sample rate is 1G, open two channels to 500M
Please point me to the specific place in the User Manual or provide screenshot of the described "open one channel" and "open two channels".

3) Do you have ability to apply external pulse of approximately 8ns and capture signal for selected 1CH and 2CH?
I need this to estimate whether the scope is suitable for our specific task.

uFedor Publish time 2022-6-22 10:44:36

Any answer?
Pages: [1]
View full version: Hantek6254 operation details